{"id":469,"date":"2023-06-01T17:07:53","date_gmt":"2023-06-01T20:07:53","guid":{"rendered":"https:\/\/ingenieria.uner.edu.ar\/nucleos\/biomecanica_computacional\/?p=469"},"modified":"2025-07-04T11:27:34","modified_gmt":"2025-07-04T14:27:34","slug":"pid-6243-biomecanica-del-contacto-lubricado-en-articulaciones-sinoviales-de-miembros-inferiores-estudio-mediante-simulaciones-computacionales-de-articulaciones-sanas-y-patologicas","status":"publish","type":"post","link":"https:\/\/ingenieria.uner.edu.ar\/nucleos\/biomecanica_computacional\/index.php\/2023\/06\/01\/pid-6243-biomecanica-del-contacto-lubricado-en-articulaciones-sinoviales-de-miembros-inferiores-estudio-mediante-simulaciones-computacionales-de-articulaciones-sanas-y-patologicas\/","title":{"rendered":"PID 6243: \u201cBiomec\u00e1nica del contacto lubricado en articulaciones sinoviales de miembros inferiores. Estudio mediante simulaciones computacionales de articulaciones sanas y patol\u00f3gicas\u201d"},"content":{"rendered":"\n<p><strong>Duraci\u00f3n: <\/strong>36 meses desde el 06\/2023<\/p>\n\n\n\n<p><strong>Financia: UNER<\/strong><\/p>\n\n\n\n<p><strong>Director:<\/strong> Jos\u00e9 Di Paolo<\/p>\n\n\n\n<p><strong>Co-directora: <\/strong>Brenda Weiss<\/p>\n\n\n\n<p><strong>Resumen:<\/strong> Las articulaciones de rodilla y cadera son articulaciones sinoviales de tipo diartrosis, es decir que permiten gran movilidad entre los huesos que la componen (f\u00e9mur y tibia en rodilla, f\u00e9mur y coxal en cadera) los cuales est\u00e1n rodeados de una c\u00e1psula fibrosa que, junto a las superficies articulares, delimitan la cavidad sinovial. Las superficies articulares se encuentran recubiertas por cart\u00edlago hialino (tambi\u00e9n llamado cart\u00edlago articular), un material deformable y poroso, formado por un entramado de mol\u00e9culas hidrof\u00edlicas que le permiten mantener un alto grado de hidrataci\u00f3n y, ante la acci\u00f3n de una carga, exudar l\u00edquido por compactaci\u00f3n hacia el<br>espacio articular. La presencia del l\u00edquido sinovial y la capacidad del cart\u00edlago hialino de exudar o absorber l\u00edquido favorecen la lubricaci\u00f3n de la articulaci\u00f3n natural, preserv\u00e1ndola con un m\u00ednimo de fricci\u00f3n entre las superficies en contacto y tasas de desgaste muy bajas; todo ello de forma \u00f3ptima en situaciones de salud articular.<\/p>\n\n\n\n<p>Estas articulaciones pueden verse afectadas por enfermedades (como artritis o artrosis), anormalidades cong\u00e9nitas, tumores o traumas, siendo generalmente la artroplast\u00eda (reemplazo) de cadera o rodilla la soluci\u00f3n cl\u00ednica seleccionada en casos irreversibles. Los implantes metal- polietileno de ultra alto peso molecular son los m\u00e1s populares para el reemplazo de articulaciones de cadera y rodilla. Alrededor del 95% de estos implantes sobreviven los 10 a\u00f1os y alrededor del 80% alcanzan los 25 a\u00f1os; sin embargo, esta vida \u00fatil resulta insatisfactoria para pacientes menores de 60 a\u00f1os, que deben someterse a nuevas intervenciones quir\u00fargicas (llamadas \u201crevisiones\u201d) para reemplazar dichos implantes. <\/p>\n\n\n\n<p>Debido a la enorme complejidad del fen\u00f3meno de lubricaci\u00f3n en las juntas sinoviales, t\u00edpicamente se desprecian\/ignoran alguno\/s de los mecanismos de lubricaci\u00f3n: las complejas caracter\u00edsticas reol\u00f3gicas del fluido sinovial o del cart\u00edlago, la intrincada geometr\u00eda de la junta de rodilla o las condiciones reales de carga, entre otros. Por lo tanto, si bien es posible delimitar las condiciones de validez de estas hip\u00f3tesis simplificadoras, como tambi\u00e9n de los resultados as\u00ed obtenidos, es evidente la necesidad de realizar una modelizaci\u00f3n del comportamiento de juntas sinoviales utilizando hip\u00f3tesis menos restrictivas.<\/p>\n\n\n\n<p>Este proyecto se orienta a investigar, desde el marco de la Mec\u00e1nica Computacional, el contacto lubricado en articulaciones naturales sinoviales de miembro inferior, tanto sanas como patol\u00f3gicas, con la doble finalidad de lograr conocimientos que puedan utilizarse para extender la duraci\u00f3n de las pr\u00f3tesis y asimismo retrasar la artroplastia.<\/p>\n\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Duraci\u00f3n: 36 meses desde el 06\/2023 Financia: UNER Director: Jos\u00e9 Di Paolo Co-directora: Brenda Weiss Resumen: Las articulaciones de rodilla y cadera son articulaciones sinoviales de tipo diartrosis, es decir que permiten gran movilidad entre los huesos que la componen (f\u00e9mur y tibia en rodilla, f\u00e9mur y coxal en cadera) los cuales est\u00e1n rodeados de [&hellip;]<\/p>\n","protected":false},"author":5,"featured_media":598,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"footnotes":""},"categories":[10],"tags":[],"class_list":["post-469","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-proyectos"],"_links":{"self":[{"href":"https:\/\/ingenieria.uner.edu.ar\/nucleos\/biomecanica_computacional\/index.php\/wp-json\/wp\/v2\/posts\/469","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ingenieria.uner.edu.ar\/nucleos\/biomecanica_computacional\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/ingenieria.uner.edu.ar\/nucleos\/biomecanica_computacional\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/ingenieria.uner.edu.ar\/nucleos\/biomecanica_computacional\/index.php\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/ingenieria.uner.edu.ar\/nucleos\/biomecanica_computacional\/index.php\/wp-json\/wp\/v2\/comments?post=469"}],"version-history":[{"count":1,"href":"https:\/\/ingenieria.uner.edu.ar\/nucleos\/biomecanica_computacional\/index.php\/wp-json\/wp\/v2\/posts\/469\/revisions"}],"predecessor-version":[{"id":470,"href":"https:\/\/ingenieria.uner.edu.ar\/nucleos\/biomecanica_computacional\/index.php\/wp-json\/wp\/v2\/posts\/469\/revisions\/470"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ingenieria.uner.edu.ar\/nucleos\/biomecanica_computacional\/index.php\/wp-json\/wp\/v2\/media\/598"}],"wp:attachment":[{"href":"https:\/\/ingenieria.uner.edu.ar\/nucleos\/biomecanica_computacional\/index.php\/wp-json\/wp\/v2\/media?parent=469"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ingenieria.uner.edu.ar\/nucleos\/biomecanica_computacional\/index.php\/wp-json\/wp\/v2\/categories?post=469"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ingenieria.uner.edu.ar\/nucleos\/biomecanica_computacional\/index.php\/wp-json\/wp\/v2\/tags?post=469"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}