{"id":896,"date":"2025-10-01T08:00:00","date_gmt":"2025-10-01T11:00:00","guid":{"rendered":"https:\/\/ingenieria.uner.edu.ar\/nucleos\/movimiento_humano\/?p=896"},"modified":"2025-10-06T15:34:40","modified_gmt":"2025-10-06T18:34:40","slug":"validation-of-a-commercial-dynamometer-for-the-assessment-of-muscle-strength-2","status":"publish","type":"post","link":"https:\/\/ingenieria.uner.edu.ar\/nucleos\/movimiento_humano\/index.php\/2025\/10\/01\/validation-of-a-commercial-dynamometer-for-the-assessment-of-muscle-strength-2\/","title":{"rendered":"Validation of a Commercial Dynamometer for the Assessment of Muscle Strength"},"content":{"rendered":"\n<h3 class=\"wp-block-heading has-ast-global-color-8-color has-text-color has-link-color wp-elements-9e18339ee4cc2320763ae58b5e1d53bc\">Lucas Dorsch, Camila Dur\u00e9, Eugenia Soledad Mu\u00f1oz Larrosa, Jesica Itat\u00ed Zuchuat, Melisa Frisoli, Dar\u00edo Cardozo, Paola Catalfamo Formento.<\/h3>\n\n\n\n<h4 class=\"wp-block-heading has-ast-global-color-8-color has-text-color has-link-color wp-elements-c691047b9104e143d44f18bdb00e2c2e\">Abstract<\/h4>\n\n\n\n<p class=\"has-text-align-left\">Numerous commercial dynamometers are available on both local and international markets for the measurement of muscle strength. These measurements can guide rehabilitation and support decision making regarding return to sports activities following injuries, such as anterior cruciate ligament (ACL) injuries. However, not all dynamometers provide information regarding the accuracy of the proposed measurements, which is a critical factor for conducting assessments in both research and clinical settings. This article aims to validate the accuracy of force measurements obtained using one dynamometer, a device developed and commercialized for measurement of muscle strength in sports. The measured forces were compared with those recorded by an Instron 3367 universal\u00a0testing machine. Six tensile tests were conducted, increasing the force from 50 N to 900 N over 60 seconds, during which 1002 data points were obtained. A BlandAltman analysis was then applied to compare the results. The findings indicate that the limits of agreement are [-2.5, 2.5] [N]. Based on these results, we concluded that the tested commercial dynamometer is a valid option for measurement of tensile forces.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"617\" height=\"327\" src=\"https:\/\/ingenieria.uner.edu.ar\/nucleos\/movimiento_humano\/wp-content\/uploads\/2025\/10\/Instron.jpg\" alt=\"\" class=\"wp-image-849\" srcset=\"https:\/\/ingenieria.uner.edu.ar\/nucleos\/movimiento_humano\/wp-content\/uploads\/2025\/10\/Instron.jpg 617w, https:\/\/ingenieria.uner.edu.ar\/nucleos\/movimiento_humano\/wp-content\/uploads\/2025\/10\/Instron-300x159.jpg 300w\" sizes=\"(max-width: 617px) 100vw, 617px\" \/><figcaption class=\"wp-element-caption\"><strong>Fig. 1.\u00a0<\/strong>Set up for the experiments. From left to right: the display showing the control software of the testing machine; the testing machine holding the WLCC01 strain gauge-based load cell in position; and the display showing the dedicated acquisition software (Load Cell v5.40) used to record load cell data.<\/figcaption><\/figure>\n\n\n\n<h4 class=\"wp-block-heading has-ast-global-color-8-color has-text-color has-link-color wp-elements-850efe65a86efbb734a28ced4061eaa4\">Keywords<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Anterior Cruciate Ligament<\/li>\n\n\n\n<li>Dynamometer<\/li>\n\n\n\n<li>Muscular Strength<\/li>\n<\/ul>\n\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/drive.google.com\/file\/d\/1Bi-a9b6Fb3CXwA0g6OGvayE0aI_u5zhZ\/view?usp=sharing\" target=\"_blank\" rel=\"noreferrer noopener\">Descargar<\/a><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Lucas Dorsch, Camila Dur\u00e9, Eugenia Soledad Mu\u00f1oz Larrosa, Jesica Itat\u00ed Zuchuat, Melisa Frisoli, Dar\u00edo Cardozo, Paola Catalfamo Formento. Abstract Numerous commercial dynamometers are available on both local and international markets for the measurement of muscle strength. These measurements can guide rehabilitation and support decision making regarding return to sports activities following injuries, such as anterior [&hellip;]<\/p>\n","protected":false},"author":5,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"footnotes":""},"categories":[7],"tags":[15],"class_list":["post-896","post","type-post","status-publish","format-standard","hentry","category-publicaciones","tag-15"],"_links":{"self":[{"href":"https:\/\/ingenieria.uner.edu.ar\/nucleos\/movimiento_humano\/index.php\/wp-json\/wp\/v2\/posts\/896","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ingenieria.uner.edu.ar\/nucleos\/movimiento_humano\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/ingenieria.uner.edu.ar\/nucleos\/movimiento_humano\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/ingenieria.uner.edu.ar\/nucleos\/movimiento_humano\/index.php\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/ingenieria.uner.edu.ar\/nucleos\/movimiento_humano\/index.php\/wp-json\/wp\/v2\/comments?post=896"}],"version-history":[{"count":1,"href":"https:\/\/ingenieria.uner.edu.ar\/nucleos\/movimiento_humano\/index.php\/wp-json\/wp\/v2\/posts\/896\/revisions"}],"predecessor-version":[{"id":898,"href":"https:\/\/ingenieria.uner.edu.ar\/nucleos\/movimiento_humano\/index.php\/wp-json\/wp\/v2\/posts\/896\/revisions\/898"}],"wp:attachment":[{"href":"https:\/\/ingenieria.uner.edu.ar\/nucleos\/movimiento_humano\/index.php\/wp-json\/wp\/v2\/media?parent=896"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ingenieria.uner.edu.ar\/nucleos\/movimiento_humano\/index.php\/wp-json\/wp\/v2\/categories?post=896"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ingenieria.uner.edu.ar\/nucleos\/movimiento_humano\/index.php\/wp-json\/wp\/v2\/tags?post=896"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}